40
Technical Data
AQUATOP T05C-T10C
Heat Pump Type AQUATOP T05C T06C T08C T10C
Model Type Compact Heat Pumps
Standard Data Heat Pumps Brine
W35 W50 W35 W50 W35 W50 W35 W50
Heating capacity (Qh) B0 kW 5.4 5.0 6.5 6.1 8.2 7.7 9.6 9.0
Cooling capacity (Qo) B0 kW 4.2 3.3 5.0 4.0 6.3 5.0 7.4 5.9
El. power consumption 1) (Pe) B0 kW 1.2 1.8 1.5 2.1 1.9 2.7 2.2 3.1
Performance rating 1) (COP) B0 (-) 4.5 2.8 4.3 2.7 4.4 2.8 4.5 2.9
Standard Data Heat Pumps Water
Heating capacity (Qh) W10 kW 7.1 6.7 8.7 8.1 11.0 10.2 12.9 12.0
Cooling capacity (Qo) W10 kW 5.9 4.9 7.2 6.0 9.1 7.5 10.8 8.9
El. power consumption 1) (Pe) W10 kW 1.2 1.8 1.5 2.1 1.9 2.7 2.2 3.1
Performance rating 1) (COP) W10 (-) 5.9 3.8 5.8 3.7 5.9 3.8 6.0 3.8
Coolant R 407 c
Oil Ester oil
Oil charge l 1.0 1.1 1.1 1.1
Charge volume coolant kg 1.4 1.7 1.85 2.0
Geothermal heating system length
(50 W/m acc. to AWP)
DN 32 m 84 100 126 2 x 74
Evaporator, Brine Side
Water content WT l 1.5 1.9 1.9 2.4
Volume flow (3.0 K Δt with B0/W35) l/h 1326 1584 1992 2352
Volume flow intermediate circuit
(3.0 K Δt with W10/W35)
l/h 1863 2281 2877 3433
Pressure loss (3.0 K Δt with B0/W35) kPa 11 6 15 10
Pressure loss (3.0 K Δt with W10/W35) kPa 22 12 31 21
Medium water/ethylene glycol % 75/25
Installed brine pump RS 25/7 RS 25/7 Top S 25/10 Top S 25/10
Residual pressure with SO/W35 kPa 46 50 95 102
Residual pressure with W10/W35 kPa 31 35 77 83
Condenser Heating Side
Water content WT l 1.8 1.8 1.8 2.0
Volume flow (10 K Δt) l/h 666 798 1008 1182
Pressure loss (10 K Δt) kPa 2 5 6 6
Medium water % 100
Installed heat pump RS 25/4 RS 25/4 RS 25/4 RS 25/4
Pressure loss 10 K Δt kPa 33 27 24 22
Usage Range
Heat source temperature min./max. °C -8 / +20 -8 / +20 -8 / +20 -8 / +20
Heating flow temperature min./max. °C 20/55 20/55 20/55 20/55
Comentarios a estos manuales