Page 46 P/N 39818D Copyright © 2001 Detection Systems, Inc. DS7080iP-32 Reference Guide
Program Address 008, digit 2, must be programmed for the
Commercial mode (digit 2 = 0).
4. Zone Programming:
The Burglar alarm output signal (whether pulsed or steady) must
be different from the Fire alarm signal.
5. Alarm Output Programming:
Alarm Output, Program Address 009, digit 1 must be programmed
as *0 (A).
10.4 Using the Ademco AB-12 Bell/Housing
1) Disconnect the wire jumper from Terminal 4 to the inner housing of the Bell Box.
2) Connect wiring between the control and Bell Box as shown above.
3) Program Zone 8 as a 24-hour zone. (Program Address 030, digit 8, must be programmed as 2).